0. RefertoLaboratorio
Definition

Referto di Laboratorio.

ShortA - Referto di Laboratorio
Logical ModelInstances of this logical model are not marked to be the target of a Reference
2. RefertoLaboratorio.header
Definition

A.1 header del Referto di Laboratorio.

ShortA.1 header del Referto di Laboratorio
Control1..1
TypeBackboneElement
4. RefertoLaboratorio.header.soggettoReferto
Definition

A.1.1 Identificativo del Paziente/Soggetto e A.1.2 relative informazioni sui contatti del Paziente/Soggetto

ShortA.1.1 - A1.2 Paziente/Soggetto del Referto di Laboratorio
Control1..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/SoggettoCura
6. RefertoLaboratorio.header.destinatario
Definition

A.1.4 Destinatario delle informazioni (destinatario o destinatari del Referto di Laboratorio, potrebbero essere identificati ulteriori destinatari, ad esempio medico di base, altro specialista), se applicabile

ShortA.1.4 Destinatario delle informazioni
Control0..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Destinatario
8. RefertoLaboratorio.header.autore
Definition

A.1.5 Autore (da cui è stato redatto il referto dei risultati di laboratorio o un sottoinsieme dei risultati)

ShortA.1.5 Autore
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Autore
10. RefertoLaboratorio.header.firmatario
Definition

A.1.6 Firmatario del documento (La persona che si assume la responsabilità di validare a livello legale il contenuto del documento)

ShortA.1.6 Firmatario del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Firmatario
12. RefertoLaboratorio.header.validatore
Definition

A.1.7 Validatore del documento

ShortA.1.7 Validatore del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Validatore
14. RefertoLaboratorio.header.metadati
Definition

A.1.8 Metadata del Referto di Laboratorio

ShortA.1.8 Metadata del Referto di Laboratorio
Control1..1
TypeBackboneElement
16. RefertoLaboratorio.header.metadati.tipo
Definition

Codice che identifica il tipo di documento. Valore fisso ""Referto di medicina di laboratorio"" - Dizionario di codifica: LOINC

ShortA.1.8.1 Tipo di documento
Control1..1
TypeCodeableConcept
18. RefertoLaboratorio.header.metadati.stato
Definition

Stato del Referto . Ad esempio, preliminare, finale. - Sistema di Codifica: hl7:DiagnosticReportStatus

ShortA.1.8.2 Stato del Referto
Control1..1
TypeCodeableConcept
20. RefertoLaboratorio.header.metadati.data
Definition

Data e ora della creazione del report dei risultati. - Sistema di Codifica: ISO 8601

ShortA.1.8.3 Data e ora della creazione del referto
Control1..1
TypedateTime
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
22. RefertoLaboratorio.header.metadati.titolo
Definition

Titolo del documento, ad esempio ""Rapporto sui risultati di laboratorio"" - Sistema di Codifica:

ShortA.1.8.4 Titolo del documento
Control0..1
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
24. RefertoLaboratorio.header.metadati.custode
Definition

Organizzazione incaricata della conservazione del referto di laboratorio - Sistema di Codifica:

ShortA.1.8.5 Custode del referto
Control0..1
TypeBackboneElement
26. RefertoLaboratorio.ordine
Definition

A.2 Informazioni sull'ordine A.3 Motivo dell'ordine

ShortA.2-A.3 Ordine
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Richiesta
28. RefertoLaboratorio.campione
Definition

A.4 Informazioni sul campione

ShortA.4 Informazioni sul campione
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Campione
30. RefertoLaboratorio.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato
32. RefertoLaboratorio.organizer
Definition

A.5 Batteria di esami

ShortA.5 Batteria di esami
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Organizer
34. RefertoLaboratorio.organizer.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control1..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato

Guidance on how to interpret the contents of this table can be found here

0. RefertoLaboratorio
Definition

Referto di Laboratorio.

ShortA - Referto di Laboratorio
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
2. RefertoLaboratorio.header
Definition

A.1 header del Referto di Laboratorio.

ShortA.1 header del Referto di Laboratorio
Control1..1
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. RefertoLaboratorio.header.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. RefertoLaboratorio.header.soggettoReferto
Definition

A.1.1 Identificativo del Paziente/Soggetto e A.1.2 relative informazioni sui contatti del Paziente/Soggetto

ShortA.1.1 - A1.2 Paziente/Soggetto del Referto di Laboratorio
Control1..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/SoggettoCura
8. RefertoLaboratorio.header.destinatario
Definition

A.1.4 Destinatario delle informazioni (destinatario o destinatari del Referto di Laboratorio, potrebbero essere identificati ulteriori destinatari, ad esempio medico di base, altro specialista), se applicabile

ShortA.1.4 Destinatario delle informazioni
Control0..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Destinatario
10. RefertoLaboratorio.header.autore
Definition

A.1.5 Autore (da cui è stato redatto il referto dei risultati di laboratorio o un sottoinsieme dei risultati)

ShortA.1.5 Autore
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Autore
12. RefertoLaboratorio.header.firmatario
Definition

A.1.6 Firmatario del documento (La persona che si assume la responsabilità di validare a livello legale il contenuto del documento)

ShortA.1.6 Firmatario del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Firmatario
14. RefertoLaboratorio.header.validatore
Definition

A.1.7 Validatore del documento

ShortA.1.7 Validatore del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Validatore
16. RefertoLaboratorio.header.metadati
Definition

A.1.8 Metadata del Referto di Laboratorio

ShortA.1.8 Metadata del Referto di Laboratorio
Control1..1
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. RefertoLaboratorio.header.metadati.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
20. RefertoLaboratorio.header.metadati.tipo
Definition

Codice che identifica il tipo di documento. Valore fisso ""Referto di medicina di laboratorio"" - Dizionario di codifica: LOINC

ShortA.1.8.1 Tipo di documento
Control1..1
TypeCodeableConcept
22. RefertoLaboratorio.header.metadati.stato
Definition

Stato del Referto . Ad esempio, preliminare, finale. - Sistema di Codifica: hl7:DiagnosticReportStatus

ShortA.1.8.2 Stato del Referto
Control1..1
TypeCodeableConcept
24. RefertoLaboratorio.header.metadati.data
Definition

Data e ora della creazione del report dei risultati. - Sistema di Codifica: ISO 8601

ShortA.1.8.3 Data e ora della creazione del referto
Control1..1
TypedateTime
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
26. RefertoLaboratorio.header.metadati.titolo
Definition

Titolo del documento, ad esempio ""Rapporto sui risultati di laboratorio"" - Sistema di Codifica:

ShortA.1.8.4 Titolo del documento
Control0..1
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
28. RefertoLaboratorio.header.metadati.custode
Definition

Organizzazione incaricata della conservazione del referto di laboratorio - Sistema di Codifica:

ShortA.1.8.5 Custode del referto
Control0..1
TypeBackboneElement
30. RefertoLaboratorio.ordine
Definition

A.2 Informazioni sull'ordine A.3 Motivo dell'ordine

ShortA.2-A.3 Ordine
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Richiesta
32. RefertoLaboratorio.campione
Definition

A.4 Informazioni sul campione

ShortA.4 Informazioni sul campione
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Campione
34. RefertoLaboratorio.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato
36. RefertoLaboratorio.organizer
Definition

A.5 Batteria di esami

ShortA.5 Batteria di esami
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Organizer
38. RefertoLaboratorio.organizer.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control1..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato

Guidance on how to interpret the contents of this table can be found here

0. RefertoLaboratorio
Definition

Referto di Laboratorio.

ShortA - Referto di Laboratorio
Control0..*
Is Modifierfalse
Logical ModelInstances of this logical model are not marked to be the target of a Reference
2. RefertoLaboratorio.header
Definition

A.1 header del Referto di Laboratorio.

ShortA.1 header del Referto di Laboratorio
Control1..1
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. RefertoLaboratorio.header.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
6. RefertoLaboratorio.header.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on RefertoLaboratorio.header.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
8. RefertoLaboratorio.header.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
10. RefertoLaboratorio.header.soggettoReferto
Definition

A.1.1 Identificativo del Paziente/Soggetto e A.1.2 relative informazioni sui contatti del Paziente/Soggetto

ShortA.1.1 - A1.2 Paziente/Soggetto del Referto di Laboratorio
Control1..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/SoggettoCura
12. RefertoLaboratorio.header.destinatario
Definition

A.1.4 Destinatario delle informazioni (destinatario o destinatari del Referto di Laboratorio, potrebbero essere identificati ulteriori destinatari, ad esempio medico di base, altro specialista), se applicabile

ShortA.1.4 Destinatario delle informazioni
Control0..1
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Destinatario
14. RefertoLaboratorio.header.autore
Definition

A.1.5 Autore (da cui è stato redatto il referto dei risultati di laboratorio o un sottoinsieme dei risultati)

ShortA.1.5 Autore
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Autore
16. RefertoLaboratorio.header.firmatario
Definition

A.1.6 Firmatario del documento (La persona che si assume la responsabilità di validare a livello legale il contenuto del documento)

ShortA.1.6 Firmatario del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Firmatario
18. RefertoLaboratorio.header.validatore
Definition

A.1.7 Validatore del documento

ShortA.1.7 Validatore del documento
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Validatore
20. RefertoLaboratorio.header.metadati
Definition

A.1.8 Metadata del Referto di Laboratorio

ShortA.1.8 Metadata del Referto di Laboratorio
Control1..1
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
22. RefertoLaboratorio.header.metadati.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
24. RefertoLaboratorio.header.metadati.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on RefertoLaboratorio.header.metadati.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
26. RefertoLaboratorio.header.metadati.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
28. RefertoLaboratorio.header.metadati.tipo
Definition

Codice che identifica il tipo di documento. Valore fisso ""Referto di medicina di laboratorio"" - Dizionario di codifica: LOINC

ShortA.1.8.1 Tipo di documento
Control1..1
TypeCodeableConcept
30. RefertoLaboratorio.header.metadati.stato
Definition

Stato del Referto . Ad esempio, preliminare, finale. - Sistema di Codifica: hl7:DiagnosticReportStatus

ShortA.1.8.2 Stato del Referto
Control1..1
TypeCodeableConcept
32. RefertoLaboratorio.header.metadati.data
Definition

Data e ora della creazione del report dei risultati. - Sistema di Codifica: ISO 8601

ShortA.1.8.3 Data e ora della creazione del referto
Control1..1
TypedateTime
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
34. RefertoLaboratorio.header.metadati.titolo
Definition

Titolo del documento, ad esempio ""Rapporto sui risultati di laboratorio"" - Sistema di Codifica:

ShortA.1.8.4 Titolo del documento
Control0..1
Typestring
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
36. RefertoLaboratorio.header.metadati.custode
Definition

Organizzazione incaricata della conservazione del referto di laboratorio - Sistema di Codifica:

ShortA.1.8.5 Custode del referto
Control0..1
TypeBackboneElement
38. RefertoLaboratorio.ordine
Definition

A.2 Informazioni sull'ordine A.3 Motivo dell'ordine

ShortA.2-A.3 Ordine
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Richiesta
40. RefertoLaboratorio.campione
Definition

A.4 Informazioni sul campione

ShortA.4 Informazioni sul campione
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Campione
42. RefertoLaboratorio.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato
44. RefertoLaboratorio.organizer
Definition

A.5 Batteria di esami

ShortA.5 Batteria di esami
Control0..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Organizer
46. RefertoLaboratorio.organizer.osservazione
Definition

A.5.2 Dettagli dell'osservazione (il rapporto può consistere di più osservazioni)

ShortA.5.2 Dettagli dell'osservazione
Control0..*
TypeBackboneElement
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
48. RefertoLaboratorio.organizer.osservazione.id
Definition

Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

ShortUnique id for inter-element referencing
Control0..1
Typestring
Is Modifierfalse
XML FormatIn the XML format, this property is represented as an attribute.
Summaryfalse
50. RefertoLaboratorio.organizer.osservazione.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

ShortAdditional content defined by implementations
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifierfalse
Summaryfalse
Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
SlicingThis element introduces a set of slices on RefertoLaboratorio.organizer.osservazione.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ url
52. RefertoLaboratorio.organizer.osservazione.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
54. RefertoLaboratorio.organizer.osservazione.data
Definition

Data e ora dell'osservazione - Sistema di codifica: ISO 8601

ShortA.5.2.1 Data dell'osservazione
Control0..*
TypeCodeableConcept
56. RefertoLaboratorio.organizer.osservazione.codice
Definition

Codice che rappresenta l'osservazione utilizzando i sistemi di codici concordati.

  • Sistema/i preferito/i: LOINC
    • Sistema/i preferito/i: NPU
    • Sistema/i preferito/i: SNOMED CT
ShortA.5.2.3 Codice dell'osservazione
Control0..*
TypeCodeableConcept
58. RefertoLaboratorio.organizer.osservazione.risultato
Definition

Risultato e codifica della misura relativa all'osservazione inclusi testo, risultati numerici e codificati. Il contenuto del risultato dell'osservazione varierà a seconda del tipo di osservazione.

  • Sistema/i preferito/i: SNOMED CT (per i risultati in scala ordinale o nominale e codifica dei risultati)
  • Sistema/i preferito/i: UCUM (per unità)
ShortA.5.2.11 Risultato dell'osservazione
Control0..*
TypeBackboneElement
60. RefertoLaboratorio.organizer.risultato
Definition

A.5 Risultati dell'esame

ShortA.5 Risultati dell'esame
Control1..*
Typehttp://hl7.it/fhir/lab-report/StructureDefinition/Risultato