HL7 FHIR Implementation Guide Laboratory Report
0.1.0 - ballot Italy flag

This page is part of the HL7 FHIR Implementation Guide Laboratory Report (v0.1.0: Release 1 Ballot 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: ServiceRequest-Lab-Esempio - JSON Representation

Raw json | Download


{
  "resourceType" : "ServiceRequest",
  "id" : "463ae6fe-60d4-4b38-84b3-1008e0925678",
  "meta" : {
    "profile" : [
      "http://hl7.it/fhir/lab-report/StructureDefinition/servicerequest-it-lab"
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: ServiceRequest</b><a name=\"463ae6fe-60d4-4b38-84b3-1008e0925678\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource ServiceRequest &quot;463ae6fe-60d4-4b38-84b3-1008e0925678&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-servicerequest-it-lab.html\">ServiceRequest - Lab Report</a></p></div><p><b>identifier</b>: id:\u00a012345\u00a0(period:\u00a02023-03-15 --&gt; 2023-04-15)</p><p><b>requisition</b>: id:\u00a01300A4000000248</p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>category</b>: Laboratory procedure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#108252007)</span></p><p><b>priority</b>: routine</p><p><b>subject</b>: <a href=\"Patient-Paziente-SSN.html\">Patient/Paziente-SSN</a> &quot; ROSSI&quot;</p><p><b>authoredOn</b>: 2023-03-15</p><p><b>reasonCode</b>: Pregestational diabetes mellitus AND/OR impaired glucose tolerance, modified White class F <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#4307007)</span></p><p><b>specimen</b>: <a href=\"Specimen-168d4960-0a0b-43af-8025-180f0965f324.html\">Specimen/168d4960-0a0b-43af-8025-180f0965f324</a></p></div>"
  },
  "identifier" : [
    {
      "value" : "12345",
      "period" : {
        "start" : "2023-03-15",
        "end" : "2023-04-15"
      }
    }
  ],
  "requisition" : {
    "value" : "1300A4000000248"
  },
  "status" : "completed",
  "intent" : "order",
  "category" : [
    {
      "coding" : [
        {
          "system" : "http://snomed.info/sct",
          "code" : "108252007",
          "display" : "Laboratory procedure"
        }
      ]
    }
  ],
  "priority" : "routine",
  "subject" : {
    "reference" : "Patient/Paziente-SSN"
  },
  "authoredOn" : "2023-03-15",
  "reasonCode" : [
    {
      "coding" : [
        {
          "system" : "http://snomed.info/sct",
          "code" : "4307007",
          "display" : "Pregestational diabetes mellitus AND/OR impaired glucose tolerance, modified White class F"
        }
      ]
    }
  ],
  "specimen" : [
    {
      "reference" : "Specimen/168d4960-0a0b-43af-8025-180f0965f324"
    }
  ]
}