HL7 FHIR Implementation Guide Dossier Farmaceutico
0.1.1 - ci-build Italy flag

HL7 FHIR Implementation Guide Dossier Farmaceutico, published by HL7 Italia. This guide is not an authorized publication; it is the continuous build for version 0.1.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-it/dossier-pharma/ and changes regularly. See the Directory of published versions

: Codice sostituzione sostanza - TTL Representation

Active as of 2024-06-24

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "codice-sostituzione-sostanza"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This case-sensitive code system <code>http://hl7.it/fhir/dossier-pharma/CodeSystem/codice-sostituzione-sostanza</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td style=\"white-space:nowrap\">A<a name=\"codice-sostituzione-sostanza-A\"> </a></td><td>Il codice inserito nel campo si riferisce ad un codice AIC, riferito allo stesso farmaco prescritto dal medico, ma che il farmacista ritiene più aggiornato come codice</td></tr><tr><td style=\"white-space:nowrap\">S<a name=\"codice-sostituzione-sostanza-S\"> </a></td><td>Il codice AIC inserito nel campo rappresenta una sostituzione di farmaco, prevista per legge, rispetto a quanto indicato dal medico prescrittore</td></tr><tr><td style=\"white-space:nowrap\">V<a name=\"codice-sostituzione-sostanza-V\"> </a></td><td>Il codice prestazione inserito nel campo è stato variato dall’erogatore specialistico rispetto a quanto prescritto dal medico</td></tr></table></div>"
  ] ; # 
  fhir:url [ fhir:v "http://hl7.it/fhir/dossier-pharma/CodeSystem/codice-sostituzione-sostanza"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "0.1.1"] ; # 
  fhir:name [ fhir:v "CodiceSostituzoneSostanza"] ; # 
  fhir:title [ fhir:v "Codice sostituzione sostanza"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:date [ fhir:v "2024-06-24T07:51:34+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "HL7 Italia"] ; # 
  fhir:contact ( [
fhir:name [ fhir:v "HL7 Italia" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://hl7.it" ]     ] )
  ] [
fhir:name [ fhir:v "HL7 Italia" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://hl7.it" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "Codice sostituzione sostanza"] ; # 
  fhir:jurisdiction ( [
    ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:3166"^^xsd:anyURI ] ;
fhir:code [ fhir:v "IT" ] ;
fhir:display [ fhir:v "Italy" ]     ] )
  ] ) ; # 
  fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # 
  fhir:content [ fhir:v "complete"] ; # 
  fhir:count [ fhir:v "3"^^xsd:nonNegativeInteger] ; # 
  fhir:concept ( [
fhir:code [ fhir:v "A" ] ;
fhir:display [ fhir:v "Il codice inserito nel campo si riferisce ad un codice AIC, riferito allo stesso farmaco prescritto dal medico, ma che il farmacista ritiene più aggiornato come codice" ]
  ] [
fhir:code [ fhir:v "S" ] ;
fhir:display [ fhir:v "Il codice AIC inserito nel campo rappresenta una sostituzione di farmaco, prevista per legge, rispetto a quanto indicato dal medico prescrittore" ]
  ] [
fhir:code [ fhir:v "V" ] ;
fhir:display [ fhir:v "Il codice prestazione inserito nel campo è stato variato dall’erogatore specialistico rispetto a quanto prescritto dal medico" ]
  ] ) . #